Product Specifications

CK4-8-15
Fundamental ItemSpecifications
Welding set data channel15 or 31 
Number of squzzing channe2
Number of pulsation3
Welding process step4 or 8
Time control Heat 1-3 time0~99cycles
Other time0(2)~99cycles
Pulsation2~99times
Current slope0-98cycles for pu or down
Current controlWelding current2.0~50.0KA
Voltage compensation controlConstant current compensation
Current detector coilWMC-451N
Additional functionExternal input / outputHeat-on outputSolid-state circuit
Pulsation-on output(Alternately switched
Weld inputEquipped
Welding step timing outputOne make-contact
Outside squeezing mode inputEquipped
Squeezing pressure control output0.00-999kN
(for15ch or 31ch)(option)
No work inputEquipped
CounterSpot counter0~99(for 15ch or 31ch)
Work counter0~999(for15ch or 31ch)
Total spot counter0~99999(for15ch or 31ch)
Step-up counter0~9999 (for3SVch)
MonitorsMemory errorSCR short-circuited 
Up./low. limit current errorCurrent checker
Full heat checkContact checker
Cooling water errorWelding power discontinuation
UP./low. limit firing angle monitorFused electrode detect / No work
(Error memory capacity : 10 points)
Data storeData backupwith flash memory
Enviormental conditionOperation temperature0~45℃
Storing temperature-10 ~ +60℃
Allowable humidity45~85% (without condensation)
Power supplyControl powerAC100V + 10% -15% 50/60Hz,30VA
Welding powerAC220V/440V +10% -20% 50/60Hz,30VA
DimensionsVertical type CK4-8-15W90*H300*D325
Lateral type CK4-8-15PW300*H90*D325
WeightVertial type / Lateral type5kg
CE2-6-7
Welding Condition SettingItemSpecification
Channel7channels 
 Squeezing channel2 channel
Weld step2 steps
Sequence step6 steps
  Time Control Weld time0~99 cycles
Other times0(2)~99cycles
Current Upslope time0~29cycles
Current ControlWelding current2.0-49.9kA (When WMC-451N is used)
Current range (secondary)5.0~50.0KA (When WMC-451N is used)
Current response speed0.5cycle
Constant voltage control and voltage compensation control can be combination
Welding detection coilWMC-451N (1pce)
CounterTotal counter0-999
MonitorConstant current monitor±5%
Full heatDetection on voltage compensation control
Over temperatureLack of cooling water , duty cycle is over.
Weld sourceWeld source detection
ThyristorShort citcuit of thyristor detection
Count upStop restaring during count up
External input&outputWeld interlock outputNon-contact circuit
Weld inputNon-voltage contact
Monitor reset inputNon-voltage contact
Release time output1a contact
Monitor error output1a contact
Squeezing outputSame voltage as input voltage of Timer
Usage EnviromentAmbient temperature0~45℃
Humidity45~85% (No condensation)
Input voltageControl input voltageAC100V~220V , 50/60Hz
Welding input voltageAC200V~220V , 380-415V , 50/60Hz
DimensionsQ185 x H300 x D245mm
(Not including attachment and terminal blocks)
Weight4kg